XG1.H Series
Sliding Door Pre-vacuum Sterilizer
Features
XG1.H Series Sliding Door Pulse Vacuum Sterilizer is fully automatic sterilizer, it is designed for the sterilization of biology products, utensils,aseptic clothes, medical instruments and dressings in fields of biologyproject, healthcare, animal laboratory and pharmaceutical ndustry, etc.
1.The sealing door is automatic up and down sliding, sealing with compressed air to reduce labor cost and it can save space.
2.Touch screen as interface makes the operation more easy.
3.The parameters such as time, temperature, pressure, etc in process can be displayed and adjusted by screen, these parameters also can be printed by built-in printer.
4.Program is fully automatic after starting, manual operation is also available.
5.It adopts SIEMENS PLC to control the process, high efficiency with the function of reliability and fl exibility.
6.The vacuum step is completed by pulse vacuum with feeding steam several times so as to ensure air exhaustion is over 99%, to avoid temperature dead angle and small volume effect to ensure the good result of sterilization.
7.Critical control components and valves are high quality imported to improve the reliability and stability of machine.
8.Chamber and jacket is fully stainless steel of 6mm thickness.
9.The door gasket is made of medical silicon rubber, it is one-step molding and without joint.
10.Shelf or loading trolley and transfer trolley is standard accessories.
11.Air compressor is optional.
12.Material for chamber, jacket and piping can be customized.
Safety Features
The process can not be started when the door is unlocked.
The door can not be opened if there is pressure in chamber for ensuring the safety of both operators and machine.
For double door type, only one door can be opened at same time.
The filtering precision of air filter can reach 0.2 micron, to ensure no second pollution after sterilization.
The door detect sensor can detect and prevent closure if there is any obstruction
Password is needed for parameters modification.
Emergency switch can stop any abnormal operation occurs.
Safety valves will release pressure of chamber and jacket if pressure is out of range.
Various alarms can stop operation and indicate the trouble spot.
Technical parameters | |
Rated working pressure: | 0.21Mpa |
Rated working temperature: | 132℃ |
Range of pulse times: | 0~99 times |
Range of time for sterilization: | 0~9999 seconds |
Range of time for drying: | 0~9999 seconds |
Safety valve(chamber & jacket): | open pressure: 0.23Mpa |
close pressure: 0.21Mpa | |
Pulse vacuum range: | positive pressure 0.065Mpa~0.09Mpa |
negative pressure –0.05Mpa~-0.09Mpa | |
Air exhausted: |
>99%(≥3 times of pulse vacuum) |