XYL-606
Fluorescence Microscope
Model:XYL-606 Fluorescence Microscope
Product Description:
XYL-606 Fluorescence Microscope is made up of the Biological microscope and Epi-fluorescence device. Epi-fluorescence widely used in biology, medicine, immunology, oncology, genetics, materials science and other fields. Conventional configuration has 5 wave bands, and B,G,BV,V,U can be switched, and meanwhile, the conventional transmission observation can be proceeded. High-quality optical system and fluorescent attachment make you observed the satisfactory fluorescent effect. It is your best choice because of humanized configuration design, convenient operation system and novel appearance.
Specification
Viewing Head
|
Compensation Free Binocular Head Inclined at 30°(50mm-75mm) |
Eyepiece
|
WF10×/22mm |
Objective
|
Infinite Apochromatic Fluorescent Objectives: 4×/N.A.O.15,10×/N.A.O.35,20×/N.A.0.6,40
× (S) /N.A.O.75
|
Nosepiece
|
Sextuple Nosepiece |
Stage
|
Double layer mechanical stage |
Stage Size: 180mm×160mm | |
Moving Range: 80mm×50mm | |
Condenser
|
N.A.1.25 Abbe condenser with iris diaphragm and filters |
Focusing
|
Coaxial coarse&fine focusing adjustment with rack and pinion mechanism.Fine focusing
scale value 0.002mm
|
Light Source
|
Transmission Illumination: Halogen Bulb 12V/30W, Brightness Adjustable |
Epi-Fluorescent Illumination: 220V(110V) .Ultra-high pressure Mercury Lamp100W/DC.Digital
display mercury lamp constant power
|
|
Fluorescent Box
|
G,B,BV,V,U Wave Band |
Optional Accessory
|
Eyepiece: WF16×/17mm,WF20×/12.5mm |
1.3Mega,2.0 Mega,3.0 Mega,5.0 Mega pixels CMOS Digital camera eyepiece | |
Infinite Plan Objectives: 4×,10×,20×,40×(s),60×(s),100×(s)oil | |
Infinite fluorescent Objectives:100×(dry)/N.A.0.9 | |
Y Wave band fluorescent box | |
Light Source: Halogen Bulb 12V/50W,12V/100W | |
Photography attachment and CCD Adapter0.5×,0.57×,0.75× |
Characteristicsand description
1.Super wide viewing field eyepiece.
2.Stray light suppression system:Leading strong stray light out of light path
and absorb it,greatly increased the Signal-to-Noise Of the imae of fluorescence microscope.
and absorb it,greatly increased the Signal-to-Noise Of the imae of fluorescence microscope.
3.High precision revoiver system:conversion of the file-band G,B,BV,V,U,flexible and soft and accurate positioning and ensure that each wave band can be llluminated by excitation light fully and equably.
4.Large N.A.Plan-achromatic fluorescent objectives,greatiy increased the fluorescent intensity.