MP551
pH/mV/ISE/Conductivity/DO Meter
Features
For multi-parameter high precision measurement laboratory measuring instrument, covering the pH, ion concentration, conductivity and dissolved oxygen, more than 10 kinds of electrochemical parameters. Suitable for petroleum, chemical, pharmaceutical, power plants and environmental protection industries in the field of education and research more widely used.
Specifications
pH | Measuring range | (-1.999 ~ 19.999)pH |
Resolution | 0.1/0.01/0.001 pH | |
Accuracy | Meter:±0.002 pH, connect meter with electrode:±0.01pH | |
Input current | ≤1×10-12 A | |
Input impendance | ≥3×1012 Ω | |
Stability | ±0.002 pH/3h | |
Temp. compensation range | (0 to 100) ℃(automatic or manual) | |
mV | Measuring range(mV/ORP/EH) | -1999.9mV ~ 0 ~ 1999.9mV |
Resolution | 0.1mV | |
Accuracy | ±0.03% FS | |
Ion Concentration | Measuring range | 0.00 ~ 14.00 pX |
Display unit | pX、mol/L、mg/L、ppm | |
Accuracy | Meter:±0.5 % reading(monovalent), ±1.0 % reading (bivalent) | |
Temp. compensation range | 0 to 60 ℃(automatic or manual) | |
Conductivity | Measuring range | Conductivity:(0.00~20.00)μS/cm (20.0~200.0)μS/cm |
(200~2000)μS/cm (2.00~20.00)mS/cm | ||
(20.0~200.0)mS/cm (200~2000)mS/cm(K=10) | ||
Resistivity:(0 ~ 100)MΩ·cm | ||
TDS: (0 ~ 100)g/L | ||
Salinity: (0 ~ 100)ppt | ||
Resolution | 0.01/0.1/1μS/cm 0.01/0.1/1 mS/cm | |
Accuracy | Meter:±0.5% FS,connect meter with electrode:±0.80% FS | |
Temp. compensation range | (0 ~ 50)℃(automatic ) | |
Electrode constant | 0.1 / 0.5 / 1 / 5 / 10 / 50 / 100 cm-1 | |
Reference temperature | 25℃、20℃ and 18℃ | |
Dissolved Oxygen | Measuring range | (0 ~ 40.00)mg/L(ppm) (0 ~ 200.0)% |
Resolution | 0.1/0.01 mg/L(ppm) 1/0.1 % | |
Accuracy | Meter:±0.10 mg/L,connect meter with electrode:±0.40 mg/L | |
Response time | ≤30 s(25℃, 90% response) | |
Residual current | ≤0.1 mg/L | |
Temp. compensation range | (0 ~ 45)℃(automatic) | |
Salinity compensation range | (0 ~ 45)ppt(automatic) | |
Air pressure compensation | (80 ~ 105)kPa(automatic) | |
Automatic calibration | Air saturated by water; water saturated by air | |
Electrode type | Polarogram type | |
Temperature | Measuring range | -10℃~ 110℃ |
Resolution | 0.1℃ | |
Accuracy | 5~ 60℃range:±0.4℃ other range:±0.8℃ | |
Other Technical Parameters: |
Data storage | 300 groups |
Storage content |
Measuring value series number, measuring value, temperature, ATC or MTC state, measuring date and time |
|
DC9V/300mA | ||
Power | RS232 | |
Communication connector | 160 × 190 × 70mm/880g | |
Size and weight | ISO9001:2008, CE and CMC | |
Quality and safety certification |
||
Working Condition | Environment temperature | 5 ~ 35 ℃(0.01grade) 15 ~ 30 ℃(0.001grade) |
Environmental humidity | ≤75% | |
IP rating | IP54 Dustproof and waterproof |
Standard Kit Includes
1. Model MP551 pH/mV/ISE/Cond/DO meter | 1set |
2. Model 602 flexible electrode holder | 1pc |
3. Model 901 intelligent stirrer | 1set |
4. 201T-M plastic pH/ATC three-in-one combination electrode | 1pc |
5. 2503-C glass pH combination electrode | 1pc |
6. MP500 temperature electrode | 1pc |
7. 2401-M conductivity electrode | 1pc |
8. DO500 DO electrode | 1pc |
9. Model 6213 double salt bridge reference electrode | 1pc |
10. pH standard buffer solution(pH4.00、pH6.86、pH9.18/50ml) | 1btl/each |
11. 1413μS/cm conductivity standard solution (50 mL) | 2btls |
12. 9V power adapter (meter use) | 1pc |
13. 6V power adapter (stirrer use) | 1pc |
14. DO503 membrane cap (DO electrode use) | 3pc |
15. DO502 DO electrode inner solution (30 mL) | 1btl |
16. Cathode polishing paper | 2pcs |
17. B628 stirring bead | 3pcs |
18. AA battery | 4units |
19. RS-232 communication cable | 1pc |
20. MP551 communication software disk | 1pc |
21. Operation manual | 1unit |
22. Brief operation instruction | 1unit |
23. Packing List | 1pc |
Optional Accessories
Accessory Categry | Description | Specifications |
pH combination electrode |
201-C plastic combination pH electrode |
Suitable for routine pH measurements, widely used, BNC connector. |
200-C plastic combination pH electrode |
Suitable for routine pH measurements, long continuous, high precision, BNC plug. |
|
206-C plastic combination pH electrode |
Smaller diameter electrode, suitable for small diameter container in a test, BNC connector |
|
201T-M plastic three-in-one combination pH electrode |
Simultaneous measurement of pH and temperature, automatic temperature compensation, BNC + RCA plugs. |
|
2501-C glass combination pH electrode |
For precise pH test, routine laboratory use, BNC plug. |
|
2503-C glass combination pH electrode |
For precise pH test, used to measure
complex samples, BNC plug. |
|
2503D-C glass combination pH electrode |
For low-temperature solution and pure water pH measurement, BNC plug. |
|
2503G-C glass combination pH electrode |
Suitable for high temperature solution pH measurements, BNC plug |
|
2503S-C glass combination pH electrode |
For acid and high-temperature solution pH measurements, BNC plug. |
|
2015P-C plane combination pH electrode |
For the surface and trace solution pH measurement, BNC plug. |
|
Ion electrode | 7801 Sodium ion electrode |
Used to test the concentration of sodium ion,BNC plug |
CA501 Calcium composite electrode |
used for testing Calcium concentration,BNC plug |
|
Calcium electrode probe | Used with CA501 electrode | |
F502 Fluoride electrode | Used to test Fluoride concentration,BNC plug | |
CL502 Chloride electrode |
Used to test the concentration of chloride ion,BNC plug |
|
BR502 Bromide electrode |
Used to test the concentration of bromide ion,BNC plug |
|
I502 Iodide Electrode |
Used to test the concentration of iodide ion,BNC plug |
|
CU502 Copper electrode |
Used to test the copper concentration, BNC plug |
|
K502 Potassium electrode |
Used to test the concentration of potassium ion,BNC plug |
|
NO502 Nitrate electrode |
Used to test the concentration of nitrate ion,BNC plug |
|
NH501 Ammonia electrode |
Used to test the ammonia concentration,BNC plug |
|
Reference Electrode |
6211 Reference electrode | Suitable for routine measurements, banana plugs. |
6212 Reference electrode |
Equipped with the 7801 sodium ion electrode, banana plugs |
|
6213 Reference electrode |
The first and second salt bridge solution
can be chosen, for all measurement occasions, banana plugs. |
|
6215 Reference electrode |
Most ion electrode for supporting the use, banana plugs |
|
Conductivity Electrode |
DJS-0.1-M Pure water conductivity electrode |
K=0.1 cm-1,Automatic temperature compensation, for testing the conductivity of high pure water, 4-pin plug |
2401-M Glass conductivity electrode |
K=1.0 cm-1,Automatic temperature compensation, precision laboratory test for conductivity, 4-pin plug. |
|
2301-M Plastic conductivity electrode |
K=1.0 cm-1,Automatic temperature compensation for laboratory and field testing, 4-pin plug. |
|
2310-M Plastic conductivity electrode |
K=10 cm-1,Automatic temperature compensation, used to test seawater and concentrated salt water, etc., 4-pin plug |
|
Glass flow cell | Equipped with DJS-0.1-M electrode | |
DO Electrode | DO500 DO electrode |
Polarographic-type DO electrode, For laboratory and field using, 8-pin plug |
DO Electrode attachment |
DO503 DO electrode membrane cap |
Combined membrane cap,Dedicated to the DO500 DO electrode, size: 3 / group |
DO502 DO electrode electrolyte |
Added electrolyte, dedicated to the DO500 DO electrode, specifications: 30mL/bottle |
|
DO501 Cathode polishing paper |
Polishing paper, dedicated to clean DO500 DO electrode cathode, Size: 2 / group. |
|
ORP Composite electrode | 301Pt-C Plastice ORP combination electrode |
ORP measurement for conventional, wide range of uses, BNC plug |
3501Pt –C Glass ORP combination electrode |
ORP measurement of routine laboratory, test stability, fast response, BNC plug |
|
Temperature Electrode |
MP500 Temperature electrode |
Stainless steel housing, fast response, high accuracy, RCA plugs |
pH Buffer | pH4.00 buffer | 500mL/250mL/50mL(bottle) |
pH6.86 buffer | 500mL/250mL/50mL(bottle) | |
pH7.00 buffer | 500mL/250mL/50mL(bottle) | |
pH9.18 buffer | 500mL/250mL/50mL(bottle) | |
pH10.01 buffer | 500mL/250mL/50mL(bottle) | |
Ion standard solution | 10-1 mol/L Na+ Standard Solution | 500mL/250mL/100mL(bottle) |
10-1 mol/L Ca2+ Standard Solution | 500mL/250mL/100mL(bottle) | |
10-1 mol/L F- Standard Solution | 500mL/250mL/100mL(bottle) | |
10-1 mol/L Cl- Standard Solution | 500mL/250mL/100mL(bottle) | |
10-1 mol/L Br- Standard Solution | 500mL/250mL/100mL(bottle) | |
10-1 mol/L I- Standard Solution | 500mL/250mL/100mL(bottle) | |
10-1 mol/L K+ Standard Solution | 500mL/250mL/100mL(bottle) | |
10-1 mol/L Cu2+ Standard Solution | 500mL/250mL/100mL(bottle) | |
10-1 mol/L Ammonium ion Standard Solution |
500mL/250mL/100mL(bottle) | |
10-1 mol/L NO3 Standard Solution | 500mL/250mL/100mL(bottle) | |
Conductivity Calibration Solution |
84 μS/cm Conductivity Calibration Solution |
500mL/250mL/50mL(bottle) |
1413 μS/cmConductivity Calibration Solution |
500mL/250mL/50mL(bottle) | |
12.88 mS/cmConductivity Calibration Solution |
500mL/250mL/50mL(bottle) | |
146.6 μS/cmConductivity Calibration Solution |
500mL/250mL/50mL(bottle) | |
1408 μS/cmConductivity Calibration Solution |
500mL/250mL/50mL(bottle) | |
12.85 mS/cmConductivity Calibration Solution |
500mL/250mL/50mL(bottle) | |
Electrode soaking |
pH(ORP)Combination Electrode Soaking Solution |
500mL/250mL/100mL(bottle) |
10-5 mol/L Sodium ion electrode soaking Solution |
Equipped with 7801Sodium electrode . 500mL/250mL/100mL(bottle) |
|
Electrode add liquid |
3.5mol/L KCl(AgClSaturated) reference solution |
250mL/50mL/30mL(bottle) |
1mol/LPotassium nitrate (KNO3) reference solution |
For chlorine, bromine, iodine and copper ion test, and equipped with 6215 reference electrode,
250mL/100mL/30mL(bottle) |
|
1mol/L Sodium chloride (NaCl) reference solution |
Test for potassium, and equipped with 6215 reference electrode, 250mL/100mL/30mL(bottle) |
|
0.1mol/L Cesium chloride (CsCl) reference solution |
Test for sodium,and equipped with 6212 reference
electrode,250mL/100mL/30mL(bottle) |
|
Ammonia electrode inner solution |
Test for ammonium ion, and equipped with NH501 ammonia electrode,250mL/100mL/30mL (bottle) |
|
Calciumelectrode inner solution |
equipped with CA501 Calcium electrode, 250mL/100mL/30mL(bottle) |
|
Electrode
add liquid |
3.5mol/L KCl(AgClSaturated) reference solution |
500mL/250mL/100mL(bottle) |
1mol/LPotassium nitrate (KNO3) reference solution |
For chlorine, bromine, iodine and copper ion test, and equipped with 6215 reference electrode, 250mL/100mL/30mL(bottle) |
|
1mol/L Sodium chloride (NaCl) reference solution |
Test for potassium, and equipped with 6215 reference electrode, 250mL/100mL/30mL(bottle) |
|
0.1mol/L Cesium chloride (CsCl) reference solution |
Test for sodium,and equipped with 6212 reference electrode, 250mL/100mL/30mL(bottle) |
|
Ammonia electrode inner solution |
Test for ammonium ion, and equipped with NH501 ammonia electrode , 250mL/100mL/30mL(bottle) |
|
Calcium electrode inner solution |
equipped with CA501 Calcium electrode, 250mL/100mL/30mL(bottle) |
|
ORP standard solution |
222 mV ORP Standard solution | 250mL/100mL/50mL(bottle) |
Electrode holder |
Model 602 Flexible Electrode Holder |
Nice appearance of the arc-type bracket, you can turn 360 degrees and vertical lift |
Model 601Stirring Type Electrode Holder |
The electrode holder and magnetic stirrer combination of new products. |
|
Model 600 Electrode Holder | Cheap simple electrode holder |