PH510T
Portable PH Meter
GENERAL FEATURES
● Color High contrast LCD touchscreen, 4.3 inches.
● Intelligent operation system provides features including user management, calibration management, electrode management, method management, data management and etc.
● Multi-reading feature allows auto-read, timed-read and continuous-read.
● Automatic/Manual temperature compensation ensures accurate results.
● Auto-hold feature senses and locks the measurement endpoint.
● Data storage 1000 sets for each parameters (GLP-compliant).
● Data analysis feature helps user review, compare and recalculate results.
● Support for USB communication.
● Auto-power off feature effectively extends the battery service life.
● Reset feature automatically resumes all settings back to factory default options.
● IP65 waterproof.
Specification
Model |
|
PH510T |
|
Parameters(uo to 12) |
|
pH/ Temp.(mV/ORP) |
|
pH |
Range |
-2.0 to 20.00pH |
● |
Resolution |
0.1,0.01,0.001 pH |
● |
|
Accuracy |
±0.002 pH |
● |
|
Calibration Points |
Up to 8 |
● |
|
Standard Customization |
Yes |
● |
|
Calibration Reminder |
Yes |
● |
|
StandardRecognition |
USA,NIST,MERK,JIS,GB,and DIN buffers |
● |
|
Slape Limit |
Yes |
● |
|
mV/ORP |
Range |
-2000.0 to 2000.0 mV |
● |
Resolution |
0.1 ,0.01mV |
● |
|
Accuracy |
±0.1 mV or±0.3% of reading whichever is greater |
● |
|
EH ORP Mode |
Yes |
● |
|
ORP Calibration Points |
1custom point(relative mV) |
● |
|
pX |
Range |
-2.00 to 20.00 |
/ |
Resolution |
0.1,0.01,0.001px |
/ |
|
Acuracy |
±0.02pX |
/ |
|
Calibration Points |
Up to 6 |
/ |
|
ISE |
Range |
1E-9 to 9.999E9 |
/ |
Units |
mol/L,mmol/L.g/L,mg/L. μg/L |
/ |
|
Resolution |
Up to 4 significant digits |
/ |
|
Accuracy |
±0.3% |
/ |
|
Calibration Points |
Up to 8 |
/ |
|
Conductivty |
Range |
0.000 μS/cm to 3000 mS/cm |
/ |
Resolution |
0.001 μS/cm minimum;changed with range |
/ |
|
Accuracy |
±0.5%FS |
/ |
|
Reference Temperature |
5,10,15,18,20,25℃ |
/ |
|
Calibration Points |
Up to 5 |
/ |
|
Calibration Reminder |
Yes |
|
|
Standard Recognition |
10μS/cm,84μS/cm,500μS/cm,1413uS/cm;12.88mS/cm |
/ |
|
Resistivity |
Range |
5.00·Qcm~ 100.00MQ·cm |
/ |
Resolution |
0.01Q·cm minimum |
/ |
|
Accuracy |
±0.5% FS |
/ |
|
TDs |
Range |
0.000mg/L~100g/L |
/ |
Resolution |
0.001mg/L minimum;changed with range |
/ |
|
Accuracy |
±0.5% FS |
/ |
|
Salinty |
Range |
(0.00~8.00)% |
/ |
Resolution |
0.01% |
/ |
|
Accuracy |
±0.1% |
/ |
|
Dissolved Oxygen Concentration |
Sensor Type |
Polarographic |
/ |
Range |
0.00 to 99.99 mg/L |
/ |
|
Resolution |
0.01mg/L |
/ |
|
Accuracy |
±0.3mg/L(0.00 to 20.00mg/L)±10%(20.00 to 99.99mg/L) |
/ |
|
Calibration Reminder |
Yes |
|
|
Calibration Points |
Air-saturated water or zero point |
/ |
|
Barometric Compensation |
yes |
/ |
|
Manual SalinityFactor Correction |
yes |
/ |
|
Saturation |
Range |
(0.0 to 600.0)% |
/ |
Resolution |
0.10% |
/ |
|
Accuracy |
±10.0% |
/ |
|
Temperature |
Range |
5 to 110℃,23 to 230℉ |
● |
Unit |
℃,℉ |
● |
|
Resolution |
0.1 |
● |
|
Relative Accuracy |
±0.2 |
● |
|
Measurement |
Reading Mode |
AutoRead( Fast, Medium,Slow), Timed, Continuous |
● |
Reading Prompts |
Reading, Stable,Locked |
● |
|
Data Management |
Data Storage |
1000 Groups |
● |
GLP Features |
Yes |
● |
|
Inputs |
pH Electrode |
BNC(Q9) |
● |
Temp.DO Probe |
4-pin aviation connector |
● |
|
Temp./EC Probe |
5-pin aviation connector |
/ |
|
Outputs |
USB |
USB 2.0 flash memony device,PC,scanner |
● |
Bluetooth |
printer |
● |
|
Display Options |
Backlight |
Yes |
● |
Auto Shut-down |
300,600,1200,1800,3600sec,off |
● |
|
IP Rating |
IP65 |
● |
|
Date and Time |
Yes |
● |
|
General |
Power |
Rechargeable Lithium batter,AC Adapter,100-240VAC input, DC5V output |
● |
Dimensions |
90x255x 40 mm |
● |
|
Weight |
500g(1.1Ib) |
● |