产品列表

所有产品 (A~Z)

联系我们

 

 销售热线:

 0571-87977725

 0571-87977729

 

 电子邮箱:

 hzckmy@gmail.com

 

 

 

CIC-D120

Ion Chromatography

Technology advantage

1.Temperature-control bipolar conductivity detector(CN 202033335U)

Greater detection range,better precise analysis.

2.Built-in circulating 3D constant temperature technology(CN 204259917U)

Temperature stability time is less than 30 mins, ensuring the accuracy and reliability of test data.

3.The world's leading full-range series of ion chromatographic columns(CN 105126936A、CN 104788603A)

High efficiency, large capacity of the columns for detecting ions of varied compositions.

4. Self-Regenerating Electrolytic Micro-membrane Suppressor(CN 102735792A)

High pressure resistance, small dead volume, highly responsive to signals.

5.Able to detect anions and cations at the ppb level.

6. Work across a variety of detectors, to expand the scope of applications of ion chromatography.

Technical Parameter:

 

 

Ion Chromatographic Pump

 

 

 

 

 

 

 

Type

 

High-pressure and low-pulse double plunger tandem advection pump

 

Maximum Pressure

35MPa

Pressure Display Accuracy

≤0.1MPa

Flow Stability

(0.2-0.5)mL/min≤3%;

(0.5-1.0)mL/min≤2%;

>1.0mL/min≤2%;

Allowable Deviation of  Flow

(0.2-0.5)mL/min , ±5%;

(0.5-1.0)mL/min, ±3%;

>1.0mL/min, ±2%;

Flow Range

0.001~9.999mL/min

Pressure Pulse

≤0.5%

Numerical-control and Electromagnetic Sample Injector

 

 

 

 

Maximum Pressure

35MPa

Contact Material of the Rotor

PEEK

Control Mode

By Stepper motor

Power Supply

24V (DC)

Digital and Temperature-control Detection System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conductivity detector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

Temperature--control and bipolar conductivity detector

Detection Mode

 

Bipolar conductivity detection

Cell Volume

≤0.8μL

Detection Range

0~45000μS/cm

Detection Resolution

≤0.0020nS/cm

Output Voltage

-6000~+6000 mV (adjustable)

Baseline Noise

≤0.05% FS

Baseline Drift

≤3% FS/30min

Operating Temperature Range

Room temperature +5 ℃ ~60 ℃

Controlling

Temperature

Accuracy

±0.01 ℃

Maximum Pressure

10.0MPa

Linear Range

≥103

Instrument  Linearity

≥0.999

Quantitative Repeatability

≤1.0%

Qualitative Repeatability

≤1.0%

Minimum Detectable Concentration

Cl-≤0.0005ug/mL;

Li+≤0.001 ug/mL;

BrO3-≤0.001 ug/mL;

Flow System

 

 

Plastic Flow Path

 

Made of PEEK materials

 

Six-way Valve

 

PEEK material, pressure 5000psi;Independent automatic collecting and flow function.

Power Supply

150W

External Size(L*W*H*)

350*470*510

Net Weight(KGS)

26

Gross Weight(KGS)

32