HT-88A/HT-88B/HT-88C
Handset infrared rays used
Summarize
This product is a type of professional handset infrared rays used Thermometer, not need to touch with testing object , with facility-using, stability-design, exactitude-measurement, wide-measuring range.It has laser ranging,apheliotropic display,automatic numerical reading lock-in and automatic tailoff.
This product can be applied to those could’t be measured by tradition method of measurement which needing touch object surface(such as moving object,electrified surface and hard-touched object.)
This product can be used in the food detection,security detection,fire detection,injection molding,vessel,spray-paint,ink and maintenance of diesel engine.
Characteristic
1、Exactitude-measurement with untouched
2、laser ranging implement
3、automatically choose measurement range,the resolution0.1ºor 1º .
4、℃/℉conversion button
5、automatic numerical value maintenance and automatic tailoff
6、compare of infrared measure temperature space and object aim: (D:S=8:1)
7、Owns apheliotropic LCD display screen
8、compare of measure space and object aim :
Model:88A/88B/88C compare of optics measure space and object aim(D:S=8:1).For example,the visual field of the instrument is 8:1,viz.,if the testing object is away from the instrument 400mm,the diameter of the testing object is not less than 50mm.
Technique Index
1、Safe Guard Requirement:
①Please use the product carefully when laser light beam is open ;
②Don’t pierce laser light beam to the eyes of man or animal ;
③Don’t reflex laser light beam to man’s eyes from the object surface ;
④Don’t pierce laser light beam to any explosive gas
2、Routine Index
Display |
3-1/2(1999count)Apheliotropic figure liquid crystal display |
Scope of temperature span measurement |
Model:88A -50~280℃ (-58~536℉) |
Model:88B -50.0~550℃ (-58.0~1022℉) |
|
Model:88C -50.0~90℃ (-58~1652℉) |
|
Responsive time |
Less than 1 second |
Sampling rate |
25times for one second |
Overtop span cue |
Display show“1” |
Display of polar |
Automatically,anode isn’t be showed,(-)means cathode. |
Emissivi ty |
Steady Emissivity is 0.95 |
Visual field |
compare of measure space and object aim(D:S)=8:1 |
Transmitting power of laser tube |
Less than1mW |
Light spectrum response |
6~14um |
tailoff |
Automatic tailoff after 7 second . |
Operational Temperature |
0℃~50℃(32℉~122℉) |
Memory Temperature |
-20℃~60℃(-4℉~140℉) |
Relative Temperature |
10%~90%RH(memory),<80%RH(operate) |
Power |
Battery is 9V,NEDA1604A 或IEC6LR61,other ones as the same specification |
Weight |
180g |
Measurement |
94×41×160mm |
Security design standard |
Accord with Europe CE Security Criterion. |
3、infrared rays used Thermometer precision Index
Model:88A
Span |
Resolution |
Degree of Accuracy |
|
-50~80℃ |
-50~-20℃ |
1℃ |
±5℃ |
-20~280℃ |
±2% of reading or±2℃ |
Span |
Resolution |
Degree of Accuracy |
|
-58~536℉ |
-58~-4℉ |
1℉ |
±9℉ |
-4~536℉ |
±2% of reading or±4℉ |
MODEL:88B
Span(Automatic Span) |
Resolution |
Degree of Accuracy |
|
-50~80℃ |
-50~-20.0℃ |
0.1℃ |
±5℃ |
-20.0~200.0℃ |
±2% of reading or±2℃ |
||
201~900℃ |
201~550℃ |
1℃ |
±2% of reading or±2℃ |
551~900℃ |
±2.5% of reading or±2℃ |
Span(Automatic Span) |
Resolution |
Degree of Accuracy |
|
-58~536℉ |
-58~-4℉ |
1℉ |
±9℉ |
-4~536℉ |
±2% of reading or±4℉ |
||
201~1022℉ |
201~1022℉ |
|
±2% of reading or±4℉ |
1023~1652℉ |
|
±2.5% of reading or±4℉ |
MODEL:88C
Span(Automatic Span) |
Resolution |
Degree of Accuracy |
|
-50.0~200.0℃ |
-50~-20℃ |
0.1℃ |
±5℃ |
-20.0~200.0℃ |
±2% of reading or±2℃ |
||
201~550℃ |
1℃ |
±2% of reading or±2℃ |
Span(Automatic Span) |
Resolution |
Degree of Accuracy |
|
-58.0~200.0℉ |
-58.0~-4.0℉ |
0.1℉ |
±9℉ |
-4.0~200℉ |
±2% of reading or±4℉ |
||
201~1022℉ |
1℉ |
±2% of reading or±4℉ |