DH-300K ,DE-120K
Precious metals Purity Detector
DH-300K DE-120K Precious metals Purity Detector
Specifications:
Features:
Measuring Procedure:
Standard Accessories:
Specification Table:
Model | DH-300K | DE-120K |
Maximum weight | 300g | 120g |
Weigh resolution | 0.01g | 0.001g |
Density resolution | 0.01g/cm3 | 0.001g/cm3 |
Measuring time | 10S | 10S |
Testing board | Unicase high-capacity plastic testing board | High-precision aluminum alloy testing board |
Model | DH-300K | DE-120K | |
Measuring type |
Traditional gold and platinum jewelry, |
Traditional gold and platinum jewelry, necklace, |
|
necklace,bracelet,ring,large bullion, craft,and gold,silver,copper,cadmium,nickel,tin.etc. |
bracelet,ring, microminiature gold and platinum craft,raw materials of precious metal and so on.Less than 3g of gold and platinum;other metal materials. |
Model | DH-300K | DE-120K | |
Gold mode | Display k value |
The K value of mixture of gold,silver,copper;mixture of gold,copper;mixture of gold,silver; |
The K value of mixture of gold, silver,copper;mixture of gold, copper;mixture of gold,silver; |
Display purity percent |
The percent of mixture of | The percent of mixture of | |
gold,silver,copper;mixture of | gold,silver,copper;mixture of | ||
gold,copper;mixture of | gold,copper;mixture of | ||
gold,silver; | gold,silver; | ||
K value range | 9K~24K | 9.0K~24K | |
Copper and silver proportion setting |
Cycle seting as user’ prefer(default 7:3) |
Cycle seting as user’ prefer(default 7:3) |
Model | DH-300K | DE-120K | |
platinum | Display value |
PT percent,density value,volume |
PT percent,density value,volume |
PT value range | Pt600 - Pt1000 | Pt600 - Pt1000 | |
Other precious metals |
function | / |
Measure the purity percent of main material in two mixture |
Display value | / | Density value,volume,content percent | |
Setting | / |
freely set the density value of main material and subordinate material |
|
Density resolution | / | 0.0001g/cm3 |
Measuring container |
unicase injection forming transparent professional measuring tank |
||
(size:length16.9mm×wide9.8mm×high8.3mm) | |||
Parameter setting |
water temperature setting,measuring medium density setting |
||
principle | Archimedes principle | ||
Memory method | Two procedures | ||
Correction method | auto correction with one button,auto detection. | ||
Output method |
output and print testing data conveniently with standard communication interface of RS-232C. |
||
Standard accessories |
Host,tank,testing board ,tweezer,thermometer,weight, wind and dust cover,a set of measuring particle parts, a set of measuring floating body parts ,power transformer |
||
wind and dust cover | Adopt the unicase dedicated wind and dust cover | ||
Option accessories | DE-40 printer | ||
power | AC~220V / 50HZ or AC~110V/60HZ | ||
Main features | Simple operation,digital display,accurate measuring,stable,durable. |