Bante900

Multi-parameter Water Quality Meter

Bante 900 multiparameter meter is capable of  measuring up to 9 water quality parameters, including pH, ORP, Ion, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen, etc.

General Features:

 Automatic Temperature Compensation  (ATC)  ensures highly accurate measurements over the entire range.

 Calibration due reminder helps you to calibrate meter regularly.

 Automatic endpoint function freezes stable measured values.

 Help message as a operational guide to helps you understand how to use meter.

 Setup menu lets user customize the calibration points, stability conditions, date and time to meet  measurement requirements.

 Expanded memory stores and recalls up to 500 readings.

 Built-in real-time clock stamps stored data to meets GLP.

 Stored data can be transferred into PC via USB communication interface.

pH Mode:

 Up to 5 points push-button calibration with auto-buffer recognition.

 Selectable pH buffer standards, resolution and temperature units.

 Automatically calculates and  displays electrode slope that helps you decide whether to replace pH electrode.

ORP Mode:

 Single point  offset calibration allows user  adjusts displayed value to a known standard.

 Absolute or Relative mV measurements provides accurate readings.

Ion Mode:

 Standard BNC connector can connects many Ion Selective Electrode.

 2 to 5 points push-button calibration from low to high concentrations.

 Selectable multiple concentration units, including ppm, mg/L, mol/L.

 Direct readout ion concentration simplifies measurement process.

 mV measurement allows user to check performance of ion electrode.

Conductivity/TDS/Salinity Mode:

 Up to 5-point push-button calibration allows user to uses customized calibration solutions.

 Adjustable TDS factors, cell constants, temperature coefficients and normalization temperature.

 Selectable linear or pure water compensation modes.

 In salinity measurement modes, selectable practical salinity (PSU) or seawater measurement standard (ppt).     

Dissolved Oxygen Mode:

 1 or 2 points auto-calibration (100% in saturated air or air-saturated water, 0% in zero oxygen solution).

 Manual salinity and barometric pressure compensation.

 Selectable readout in ppm, mg/L or percentage saturation.

Specifications:

Model

 

Bante900

pH

   

Range

 

-2.000~20.000pH

Accuracy

 

±0.002pH

Resolution

 

0.1, 0.01, 0.001pH

Calibration Points

 

1 to 5 points

Calibration Solutions

 

USA, NIST, DIN or User-defined

Temperature Compensation

 

0~100°C, 32~212°F

Compensation Mode

 

Manual or Automatic

mV

   

Range

 

-1999.9~1999.9mV

Accuracy

 

±0.2mV

Resolution

 

0.1, 1mV

Calibration Points

 

1 point (Only for Relative mV mode)

Calibration Range

 

±200mV

Ion

   

Range

 

0.001~19999ppm, mg/L, mol/L (Refer to the range of ISE)

Accuracy

 

±0.5% F.S (Monovalent), ±1% F.S (Divalent)

Resolution

 

0.001, 0.01, 0.1, 1

Calibration Points

 

2 to 5 points

Calibration Solutions

 

0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L

Temperature Compensation

 

0~100°C, 32~212°F

Compensation Mode

 

Manual or Automatic

Conductivity

   

Range

 

0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm

Accuracy

 

±0.5% F.S

Calibration Points

 

1 to 5 points

Calibration Solutions

 

10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm

Temperature Compensation

 

0~100°C, 32~212°F, Manual or Automatic

Temperature Coefficient

 

0.0~10.0%/°C

Compensation Modes

 

Linear or Pure Water

Cell Constant

 

K=0.1, 1, 10 or User-defined

Normalization Temperature

 

20°C or 25°C

TDS

   

Range

 

0~10ppt (Max. 20ppt, depending on factor setting)

Accuracy

 

±1% F.S

TDS Factor

 

0.1~1.0 (Default 0.5)

Salinity

   

Range

 

0~10ppt (Max. 80ppt)

Accuracy

 

±1% F.S

Measurement Modes

 

Seawater or Practical Salinity

Resistivity

   

Range

 

0~100MΩ

Accuracy

 

±1% F.S

Resolution

 

0.01, 0.1, 1

Dissolved Oxygen

   

Range

 

0.00~20.00mg/L (or ppm)

Accuracy

 

±0.2mg/L

Resolution

 

0.01mg/L

Calibration Points

 

1 or 2 points

Temperature Compensation

 

0~50°C, 32~122°F, Automatic

Pressure Correction

 

60.0~112.5kPa, 450~850mmHg

Salinity Correction

 

0~50g/L

% Saturation of Oxygen

   

Range

 

0.0~200.0%

Accuracy

 

±2.0%

Resolution

 

0.1, 1%

Temperature

   

Range

 

0~105°C, 32~221°F

Accuracy

 

±0.5°C, ±0.9°F

Resolution

 

0.1°C

Calibration Points

 

1 point

Calibration Range

 

Measured value ±10°C

Others

   

Hold Function

 

Manual or Automatic

Stability Conditions

 

Low or High

Calibration Due

 

0 to 31 days

Power Off

 

Manual or Automatic (10, 20, 30 minutes)

Reset Function

 

Yes

Memory

 

Stores up to 500 data sets

Output

 

USB Communication Interface

Connector

 

BNC, 6-pin Mini Plug

Display

 

LCD (130×110mm)

Power Requirements

 

DC5V, using AC adapter, 220VAC/50Hz

Dimensions

 

210(L)×188(W)×60(H)mm

Weight

 

1.5kg