You are here: Home > Products > Chemical > Chromatographic instrument > Liquid Chromatograph > HPLC > LC-10Tvp 1.2Products
LC-10Tvp 1.2
High Pressure Solvent Delivery System
LC-10Tvp High Pressure Solvent Delivery System
Summary
Pump was developed on the basis of STI501 Liquid Chromatography, adopted advanced
technology and design of the United States.
LC-10 Tvp Liquid Pump can be connected to any sort of Liquid detector, so widely applied in the field of
HPLC, laboratory chemical reaction infusion and chromatography and etc.
Feature
Improve the maximum limited pressure by precise tranducer
Accord with GMP/GLP, ISO9001, 21 CFR Part II with CDS (Software)
Online Washing Device while analysis
Self-priming pump head requires no manual priming
Available with micro, analytical, semi-prep, and prep pump heads
Programmable solvent compressibility compensation
Easy maintenance and service for all wetted parts
Specification
Flow Range: 0.001 – 9.999 ml/min
Delivery method: Double piston ( Main & Auxiliary)
Pump head: 10ml SST/Peek analytical
Accuracy: ± 1% or ± 2μL/min, whichever is greater
± 1% or ± 1μL/min, whichever is greater (Micro)
Flow rate settings: 0 - 0.10 mL/min. 0.001 inc.
0.10 – 0.90 mL/min. 0.010 inc.
1.0 mL/min.+ 0.10 inc.
Precision: 0.1% RSD
Pmax: 9999 psi
System connections: 1/16’’ capillaries
Dimensions: 130 mm x 260 mm x 420 mm
Weight: 11 kg
Power input: 85 to 264 VAC, 47 to 63 Hz, 60 Watts
Display: 300mm
SPD-10Tvp UV-VIS Spectrophotometric Detector
Summary
SPD-10Tvp UV-VIS can be connected to any sort of liquid pump, accuracy wavelength, high
sensitivity, widely linear rage. This is a cost-effective and reliable, practical, economic testing unit.
Accord with GMP/GLP, ISO9001, 21 CFR
Part II with Chromatography Data System (Software).
Feature
Unique pool structure ensures the accuracy and sensitivity of the instrument
Easy maintenance and service for all wetted parts
High-quality structure
Long life deuterium lamp
Easily replace
Advanced design
Specification
Wavelength: 190-700 nm
Spectral bandwidth: 6 nm
Wavelength Accuracy: ≤±1 nm
Wavelength Reproducibility: ≤± 0.1 nm
Flow pool volume: 8 μ L
Optical path: 10 mm
Dynamic Noise: ≤± 0.75×10-5AU (Methanol, 1ml/min, 254nm, 20°C)
Static Noise: ≤± 0.5×10-5AU(Empty pool, Response time 1 s, 20 °C)
Dynamic Drifting: ≤± 1×10-4AU (Methanol, 1ml/min, 254nm, 20°C)
Static Drifting: ≤± 0.5×10-4AU(Empty pool, Response time 1 s, 20 °C)
Qualitative repeatability: RSD ≤ 0.1%
Quantitative repeatability: RSD ≤ 0.5%
Dimensions: 130H x 260W x 420 D, (mm)
Weight: 11 kg