YD200

Lab Water Hardness Meter

Introduction

●Benchtop meter for measurement of water hardness (the total concentration of calcium ion and magnesium ion).
●Electrode adopts model 601-F water hardness combination electrode with patent structure. It consists of measurement electrode, reference electrode and temperature probe. Replaceable measuring head, steady potential, fast response, easy to use.
●Meter adopts intelligent chip design, automatic calibration, automatic temperature compensation, time display, data storage RS232 output, etc.
● Ability to switch among eight units: mmol/L, mg/L (CaCO3), mg/L (CaO), mmol/L (Boiler) and mg/L (Ca). Three options of three units: ºfH(France)、ºdH (Germany)and ºeH(UK) from WH-Link communication software.
●Equipped with B1、B2 and B3 calibration solution.
●Equipped with WH-Link communication software, connect testing data of meter to computer.
 

Specification

Water Hardness Measuring range

0 ~ 10mmol/L        

0 ~ 401mg/L(Ca)

 

0 ~ 1000mg/L(CaCO3); 

0 ~ 100ºfH(France Degree)

 

0 ~ 561mg/L(CaO)    

0 ~ 56ºdH(German Degree)

 

0 ~ 20mmol/L(Boiler)  

0 ~ 70ºeH (England Degree)

Resolution 0.01 and 0.1 water hardness units
Accuracy ±5% FS
Temp. compensation 5 ~ 50)℃((automatic))
Calibration Solution B1 Calibration Solution — 2.00×10-2 mmol/L
  B2 Calibration Solution — 2.00×10-1 mmol/L
  B3 Calibration Solution — 2.00 mmol/L
 

B3Calibration Solution also can be used 

for the soaking solution of electrode

Calibration Mode

(a)B1/B2 Calibration—using B1 and 

B2 Calibration Solution

suitable for < 2.00×10-2 mmol/L low 

concentration water quality

for example, boiler water.

 

(b)Calibration—using B2 and 

B3 Calibration Solution

suitable forgeneral water quality.

Temperature Measuring range 0 ~ 60
Resolution 0.1
Accuracy ±0.5

Other Technical 

Parameter

Data storage 128 groups
Content Storage

serial number of measuring value, 

measuring value, units, temperature, 

ATC or MTC, date, time and calibration way.

Communication 

Connector

RS232
Power DC9V
Dimension and weight (160×190×70)mm/750g
Quality and safe certificate IISO9001:2000 and CE
working conditions Ambient temperature (5~35)
ambient humidity ≤85%RH
 

Standard Kit Includes

1. Model YD300 water hardness meter 1set
2.Model 601-F water hardness electrode( With two measruing heads and one screw plug ) 1pc
3. Model 602 Flexible electrode holder 1pc
4.250mL water hardness calibration solution (B1, B2 and B3) 1btl/each
5.20mL test cup 4pcs
6. Test cup pedestal 1pc
7. WH-Link communication software 1 pc
8. RS-232 communication cable 1pc
9. Operation manual 1book
 

Optional Accessories

Accessory Category Description Specification

Water hardness 

electrode

601-F water 

hardness electrode

Suited for measurement of 

total concentration of calcium 

ion and magnesium ion, 

match YD200 meter, BNC+RCA connector

Water hardness 

calibration solution

Water hardness 

alibration solution B1

2.00×10-2 mmol/L500mL/250mL/100mLbottle
 

Water hardness 

calibration solution B2

2.00×10-1 mmol/L500mL/250mL/100mLbottle
 

Water hardness

 calibration solution B3

2.00 mmol/L500mL/250mL/100mLbottle
  Plasic test cup Specification20mL
Accessories
  Test cup base Place test cup on the base