YD200
Lab Water Hardness Meter
Introduction
Specification
Water Hardness | Measuring range |
(0 ~ 10)mmol/L; (0 ~ 401)mg/L(Ca); |
(0 ~ 1000)mg/L(CaCO3); (0 ~ 100)ºfH(France Degree); |
||
(0 ~ 561)mg/L(CaO); (0 ~ 56)ºdH(German Degree); |
||
(0 ~ 20)mmol/L(Boiler); (0 ~ 70)ºeH (England Degree)。 |
||
Resolution | 0.01 and 0.1 water hardness units | |
Accuracy | ±5% FS | |
Temp. compensation | (5 ~ 50)℃((automatic)) | |
Calibration Solution | B1 Calibration Solution — 2.00×10-2 mmol/L | |
B2 Calibration Solution — 2.00×10-1 mmol/L | ||
B3 Calibration Solution — 2.00 mmol/L | ||
(B3Calibration Solution also can be used for the soaking solution of electrode) |
||
Calibration Mode |
(a)B1/B2 Calibration—using B1 and B2 Calibration Solution, suitable for < 2.00×10-2 mmol/L low concentration water quality, for example, boiler water. |
|
(b)Calibration—using B2 and B3 Calibration Solution, suitable forgeneral water quality. |
||
Temperature | Measuring range | 0 ~ 60℃ |
Resolution | 0.1℃ | |
Accuracy | ±0.5℃ | |
Other Technical Parameter |
Data storage | 128 groups |
Content Storage |
serial number of measuring value, measuring value, units, temperature, ATC or MTC, date, time and calibration way. |
|
Communication Connector |
RS232 | |
Power | DC9V | |
Dimension and weight | (160×190×70)mm/750g | |
Quality and safe certificate | IISO9001:2000 and CE | |
working conditions | Ambient temperature | (5~35)℃ |
ambient humidity | ≤85%RH |
Standard Kit Includes
1. Model YD300 water hardness meter | 1set |
2.Model 601-F water hardness electrode( With two measruing heads and one screw plug ) | 1pc |
3. Model 602 Flexible electrode holder | 1pc |
4.250mL water hardness calibration solution (B1, B2 and B3) | 1btl/each |
5.20mL test cup | 4pcs |
6. Test cup pedestal | 1pc |
7. WH-Link communication software | 1 pc |
8. RS-232 communication cable | 1pc |
9. Operation manual | 1book |
Optional Accessories
Accessory Category | Description | Specification |
Water hardness electrode |
601-F water hardness electrode |
Suited for measurement of total concentration of calcium ion and magnesium ion, match YD200 meter, BNC+RCA connector |
Water hardness calibration solution |
Water hardness alibration solution B1 |
2.00×10-2 mmol/L,500mL/250mL/100mL(bottle) |
Water hardness calibration solution B2 |
2.00×10-1 mmol/L,500mL/250mL/100mL(bottle) | |
Water hardness calibration solution B3 |
2.00 mmol/L,500mL/250mL/100mL(bottle) | |
Plasic test cup | Specification:20mL | |
Accessories | ||
Test cup base | Place test cup on the base |