You are here: Home > Products > Specialty > Drilling Fluids & Oil Well > Electrical Stability / Resistivity Tester > Electrical Stability Tes...Products
Electrical Stability Tester (EST)
Electrical Stability Tester (EST)
Summery
The electrical stability (ES) of an oil-based drilling fluid is related to the stability of the emulsion and oil-wetting capability.
The Electrical Stability Tester for use with oil-based drilling fluids. Mud engineers depend on the electrical stability test to monitor a fluid's emulsion stability and oil-wetting capability. The new tester is simpler to operate and can be used in the lab or in the field anywhere in the world.
The Electrical Stability Tester (EST) conforms to the test procedure described in API Recommended Practice 13B-2. It operates on external power or two nine volt batteries. The EST is calibrated in peak volts which is the maximum voltage that the fluid experiences between the two electrodes. Peak voltage may be converted to Root Mean Square (RMS) voltage by multiplying the peak voltage by 0.7071.
Features
Internal power supply and built in AC power plug allow universal operation
Power requirements - 100 to 240 VAC, 50/60 Hz, 10 watt
Self-calibration for immediate performance checks
Large backlit display is easy to read, even in low light
Components
1. Probe with Cable
2. Calibration Standard for ES Meter.
3. Switch - Push Button - On / Off
4. Switch Boot
Specifications
Part No. | Model | Description & Technical Parameters | Remark |
147-50 | EST | Output Frequency:340 ± 2 Hz (0-2000v) | |
Output wave form :Sinusoidal | |||
Output voltage range:0 to 2025 V ± 25 V peak to ground (1432 RMS) | |||
Breakdown peak output current :61 micro-amps (1.59mm) | |||
Voltage ramp rate :150 ± 10 V/second | |||
Power supply :AC 230V, Internal 27 V batteries | |||
Battery life :Approximately 500 tests | |||
Dimensions:25*15*12cm (9.8in*5.9*4.7in) | |||
Complete Weight 11 lbs (5 kg) | |||
Accuracy:Cal. Standard; ± 10 V - sample, ± 3% of reading | |||
Repeatability:Cal. Standard; ± 5 V - sample, ± 2% of reading | |||
Operating temperature range. :32° to 122°F (0° to 50°C) |