Bante903
Benchtop pH/ORP/DO Meter
pH Mode:
• High accuracy benchtop multiparameter water quality meter is equipped with a large backlit LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer standards (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode slope display helps user decide whether to replace sensor.
ORP Mode:
• Single point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt measurement modes provide accurate ORP readings.
Dissolved Oxygen Mode:
• 1 or 2 points calibration using air-saturated water and zero oxygen solution.
• Manual salinity and barometric pressure compensation improve the measurement accuracy.
Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration corrects temperature deviation.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Automatic electrode diagnosis shows zero point offset and slope of the electrode.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 11 parameters, including the calibration points, resolutions, stability conditions, measurement units, etc.
• Reset feature automatically resumes all parameters back to factory default options.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.
Specification:
Model | Bante903 |
pH | |
Range | -2.000~20.000pH |
Accuracy | ±0.002pH |
Resolution | 0.1, 0.01, 0.001pH |
Calibration Points | 1 to 5 points, USA, NIST, DIN Standards |
Temperature Compensation | 0~100°C, 32~212°F, Manual or Automatic |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1, 1mV |
Calibration Points | 1 point (Only for Relative mV mode) |
Calibration Range | ±200mV |
Dissolved Oxygen | |
Range | 0.00~20.00mg/L (or ppm) |
Accuracy | ±0.2mg/L |
Resolution | 0.01mg/L |
Calibration Points | 1 or 2 points |
Temperature Compensation | 0~50°C, 32~122°F |
Pressure Correction | 60.0~112.5kPa, 450~850mmHg |
Salinity Correction | 0~50g/L |
% Saturation of Oxygen | |
Range | 0.0~200.0% |
Accuracy | ±2.0% |
Resolution | 0.10% |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Points | 1 point |
Calibration Range | Measured value ±10°C |
Others | |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC, 6-pin Mini Plug |
Display | LCD |
Power Requirements | DC5V, using AC adapters, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Order Information:
Order Code | Accessories |
Bante903-CN | E201-BNC pH Electrode |
DO100 Dissolved Oxygen Probe (Made in US) | |
TP-10K Temperature Probe | |
pH Buffer Solutions (pH4.01/7.00/10.01) | |
DO Filling Solution | |
DO Cap Membrane | |
USB Cable | |
DC5V Power Adapters | |
Bante903-UK | P11 pH Electrode (Made in UK) |
DO100 Dissolved Oxygen Probe (Made in US) | |
TP-10K Temperature Probe | |
pH Buffer Solutions (pH4.01/7.00/10.01) | |
DO Filling Solution | |
DO Cap Membrane | |
USB Cable | |
DC5V Power Adapters |