PH600L
Benchtop PH Meters
Features:
● Color High contrast LCD touchscreen, 7.0 inches.
● Intelligent operation system provides features including user management, calibration management, electrode management, method management, data management and etc.
● Multi-reading feature allows auto-read, timed-read and continuous-read.
● Automatic/Manual temperature compensation ensures accurate results.
● Auto-hold feature senses and locks the measurement endpoint.
● Data capacity of up to 1000 sets for each parameter (GLP-compliant).
● Data analysis feature helps user review, compare and recalculate results.
● Data can be transferred to PC or printer by USB or RS-232 communication interfaces.
● Automation measurement.
pH module / PH600L
● 1-6 points calibration with auto-buffer recognition.
● Selectable pH buffer groups, including NIST, DIN, GB.
● User-defined pH buffer or buffer group is supported.
● Automatic electrode diagnosis with pH slope and offset display.
Specifications:
Model |
PH600L |
● |
|
Parameters (up to 12) |
pH/Temp.(mV) |
● |
|
pH |
Range |
2.000 to 20.000 pH |
● |
Resolution |
0.1,0.01,0.001pH |
● |
|
Accuracy |
±0.002 pH |
● |
|
Slope Limit |
Yes |
● |
|
mV/ORP |
Range |
2000.00 to 2000.00 mV |
● |
Resolution |
0.1,0.01 mV |
● |
|
Accuracy |
±0.1 mV or ±0.03 % |
● |
|
EH ORP Mode |
Yes |
/ |
|
ORP Calibration Points |
1-2 custom point (relative mV |
/ |
|
px |
Range |
-2.000 to 20.000 px |
/ |
Resolution |
0.1,0.01,0.001 px |
/ |
|
Accuracy |
±0.002 pX |
/ |
|
Calibration Points |
Up to 6 |
/ |
|
ISE |
Range |
0~19990 |
/ |
Units |
mo/L, mmol/L, g/L, mg/L, μg/L |
/ |
|
Resolution |
Up to 4 significant digits |
/ |
|
Accuracy |
±0.3% |
/ |
|
Calibration Points |
Up to 6 |
/ |
|
Conductivity |
Range |
0.0 μS/cm to 3000 mS/cm |
/ |
Resolution |
0.001 μS/cm minimum; changed with range |
/ |
|
Accuracy |
+±0.5% FS |
/ |
|
Reference Temperature |
5,10,15,18,20,25C |
/ |
|
Calibration Points |
Up to 5 |
/ |
|
Calibration Reminder |
No |
/ |
|
Standard Recognition |
146.5uS/cm,1408μS/cm,12.85mS/cm, 1.3mS/cm |
/ |
|
Resistivity |
Range |
5.00 Ω-cm~100.00 MQ cm |
/ |
Resolution |
0.01 Qcm minimum; |
/ |
|
Accuracy |
±0.5% FS |
/ |
|
DS |
Range |
0.000 mg/L~1000 g/L |
/ |
Resolution |
0.001ppm minimum; changed with range |
/ |
|
Accuracy |
±0.5% |
/ |
|
Salinty |
ype |
NaCl% |
/ |
Range |
(0.00~8.00)% |
/ |
|
Resolution |
0.01% |
/ |
|
Accuracy |
±0.1% |
/ |
|
DissolvedOxygenConcentration |
Sensor Type |
Polarographic |
/ |
Range |
0.00 to 99.99 mg/L |
/ |
|
Resolution |
0.01 mg/L |
/ |
|
Accuracy |
±0.1 mg/L |
/ |
|
Calibration Reminder |
Yes |
/ |
|
Calibration Points |
Air-saturated water or zero point |
/ |
|
Barometric Compensation |
Yes |
/ |
|
Manual Salinity Factor Correction |
Yes |
/ |
|
% Saturation |
Range |
(0.0 to 600)% |
/ |
Resolution |
0.10% |
/ |
|
Accuracy |
±10.0% |
/ |
|
Temperature |
Range |
-5 to 130℃ |
● |
Unit |
℃ |
● |
|
Resolution |
0.1 |
● |
|
Accuracy |
±0.1 |
● |
|
Measurement |
Reading Mode |
Auto Read( Fast, Medium, Slow), Timed, Continuous |
● |
Reading Prompts |
Reading, Stable, Locked |
● |
|
Temp. Compensation |
ATC,MTC |
● |
|
DataManagement |
Data Storage |
100 Groups |
● |
GLP Features |
Yes |
● |
|
Log Management |
Yes |
● |
|
inputs |
pH Electrode |
BNC(Q9) |
● |
Temp.DO Probe |
6-pin MiniDIN |
● |
|
Temp./EC. Probe |
8-in MiniDIN |
/ |
|
Outputs |
USB,RS 232 |
USB 2.0 flash memory device, printer,PC |
● |
DisplayOptions |
Backlight |
Yes |
● |
Auto Shut-down |
1~60 min, off |
● |
|
IP Rating |
IP54 |
● |
|
Date and Time |
Yes |
● |
|
General |
Power |
AC Adapter,100-240 VAC input,DC24V output |
● |
Dimensions |
280×280×130 mm |
● |
|
Weight |
2500g(5.51 Ib) |
● |