CIC-D120
Ion Chromatography
Technology advantage:
1.Temperature-control bipolar conductivity detector(CN 202033335U)
Greater detection range,better precise analysis.
2.Built-in circulating 3D constant temperature technology(CN 204259917U)
Temperature stability time is less than 30 mins, ensuring the accuracy and reliability of test data.
3.The world's leading full-range series of ion chromatographic columns(CN 105126936A、CN 104788603A)
High efficiency, large capacity of the columns for detecting ions of varied compositions.
4. Self-Regenerating Electrolytic Micro-membrane Suppressor(CN 102735792A)
High pressure resistance, small dead volume, highly responsive to signals.
5.Able to detect anions and cations at the ppb level.
6. Work across a variety of detectors, to expand the scope of applications of ion chromatography.
Technical Parameter:
Ion Chromatographic Pump
|
Type |
High-pressure and low-pulse double plunger tandem advection pump
|
||
Maximum Pressure |
35MPa |
|||
Pressure Display Accuracy |
≤0.1MPa |
|||
Flow Stability |
(0.2-0.5)mL/min≤3%; (0.5-1.0)mL/min≤2%; >1.0mL/min≤2%; |
|||
Allowable Deviation of Flow |
(0.2-0.5)mL/min , ±5%; (0.5-1.0)mL/min, ±3%; >1.0mL/min, ±2%; |
|||
Flow Range |
0.001~9.999mL/min |
|||
Pressure Pulse |
≤0.5% |
|||
Numerical-control and Electromagnetic Sample Injector
|
Maximum Pressure |
35MPa |
||
Contact Material of the Rotor |
PEEK |
|||
Control Mode |
By Stepper motor |
|||
Power Supply |
24V (DC) |
|||
Digital and Temperature-control Detection System
|
Conductivity detector
|
Type |
Temperature--control and bipolar conductivity detector |
|
Detection Mode
|
Bipolar conductivity detection |
|||
Cell Volume |
≤0.8μL |
|||
Detection Range |
0~45000μS/cm |
|||
Detection Resolution |
≤0.0020nS/cm |
|||
Output Voltage |
-6000~+6000 mV (adjustable) |
|||
Baseline Noise |
≤0.05% FS |
|||
Baseline Drift |
≤3% FS/30min |
|||
Operating Temperature Range |
Room temperature +5 ℃ ~60 ℃ |
|||
Controlling Temperature Accuracy |
±0.01 ℃ |
|||
Maximum Pressure |
10.0MPa |
|||
Linear Range |
≥103 |
|||
Instrument Linearity |
≥0.999 |
|||
Quantitative Repeatability |
≤1.0% |
|||
Qualitative Repeatability |
≤1.0% |
|||
Minimum Detectable Concentration |
Cl-≤0.0005ug/mL; Li+≤0.001 ug/mL; BrO3-≤0.001 ug/mL; |
|||
Flow System
|
Plastic Flow Path
|
Made of PEEK materials
|
||
Six-way Valve
|
PEEK material, pressure 5000psi;Independent automatic collecting and flow function. |
|||
Power Supply |
150W |
|||
External Size(L*W*H*) |
350*470*510 |
|||
Net Weight(KGS) |
26 |
|||
Gross Weight(KGS) |
32 |