GENERAL FEATURES

● Color High contrast LCD touchscreen, 4.3 inches.

● Multi-reading feature allows auto-read, timed-read and continuous-read.

● Automatic/Manual temperature compensation ensures accurate results.

● Auto-hold feature senses and locks the measurement endpoint.

● Data capacity of up to 1000 sets for each parameters (GLP- compliant).

● Support for USB communication.

● Auto-power off feature effectively extends the battery service life.

● Reset feature automatically resumes all settings back to factory default options.

● IP65 waterproof.


pH

● 1-5 points calibration with standard recognition.

● Selectable pH buffer groups, including NIST, DIN, GB.

● Automatic electrode diagnosis with pH slope and offset display


Conductivity

● 1-3 points calibration with standard recognition.

● Settable parameters, including cell constant, temperature compensation coefficient, and TDS factor.

● Temperature compensation type (none, linear, pure water).


Ion

● 1-5 points calibration.

● Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, etc.

● Measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.

● Over 10 methods are built-in, including F- , Cl- , Br- , I- , NO3- , BF4- , NH4+ , K+ , Na+ , Ca2+, Cu2+, Pb2+, Ag+ and etc.; user-defined method is supported.


DO

● Support for air-saturated water or zero oxygen calibration.

● Automatic/Manual barometric pressure compensation.

● Manual Salinity Factor Correction.

● Selectable pressure unit, including kPa, mbar, Torr, Atm.


Specifications

Model

M310T

Parameters

pH/EC/ISE/DO/Temp. (mV/pX/Resistivity/TDS/Sal./DO Saturation)

pH

Range

-2.00 to 20.00pH

Resolution

0.1, 0.01 pH

Accuracy

±0.01 pH

Calibration Points

Up to 5

Standard Customization

Yes

Calibration Reminder

Yes

Standard Recognition

NIST, GB and DIN buffers

Slope Limit

Yes

mV

Range

-2000.0 to 2000.0 mV

Resolution

0.1 mV

Accuracy

±0.3 mV or ±0.1%

pX

Range

-2.00 to 20.00 pX

Resolution

0.1, 0.01 pX

Accuracy

±0.01 pX(±0.01 pX)

Calibration Points

Up to 5

ISE

Range

1E-9 to 9.999E9

Units

mol/L, mmol/L, g/L, mg/L, μg/L

Resolution

Up to 4 significant digits

Accuracy

±0.5%

Calibration Points

Up to 5

Conductivity

Range

0.000 μS/cm to 1000 mS/cm

Resolution

0.001 μS/cm minimum,

various with range selection

Accuracy

±1.0% FS

Reference Temperature

20, 25 ºC

Calibration Points

Up to 3

Standard Recognition

84μS/cm, 1413μS/cm, 12.88mS/cm

Resistivity

Range

5.00 Ω ·cm~20.00 MΩ ·cm

Resolution

0.01Ω ·cm minimum,

Accuracy

±1.0% FS

TDS

Range

0.00mg/L~300g/L

Resolution

0.01mg/L minimum, 3 significant digits

Accuracy

±1.0%

Salinity

Range

(0.00~8.00)%

Resolution

0.01%

Accuracy

±0.2%

Dissolved

Oxygen Concentration

Sensor Type

0.00 to 50.00 mg/L

Range

0.00 to 50.00 mg/L

Resolution

0.01mg/L

Accuracy

±0.1mg/L

Calibration Points

Air-saturated water or zero point

Barometric Compensation

Yes

Manual Salinity Factor Correction

Yes

Saturation

Range

(0.0 to 300.0)%

Resolution

0.10%

Accuracy

±2.0%

Temperature

Range

-5 to 110 ºC, 23.0 to 230 ºF

Unit

ºC, ºF

Resolution

0.1

Relative Accuracy

±0.2

Measurement

Reading Mode

Auto-Read (Fast, Medium, Slow), Timed, Continuous

Reading Prompts

Reading, Stable, Locked

Temp. Compensation

ATC, MTC

Data management

Data Storage

1000 Groups

GLP Features

Yes

Inputs

pH Electrode

BNC(Q9)

DO with Temp. Probe

4-pin aviation connector

Conductivity with Temp. Probe

5-pin aviation connector

Outputs

USB

PC, printer

Display options

Backlight

Yes

Auto Shutdown

300, 600, 1200, 1800, 3600sec., off

IP Rating

IP65

Date and Time

Yes

General

Power

Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output

Dimensions

90 x 255 x 40 mm

Weight

500g (1.1 lb)