S3000-VIS/S3000-UV/S3000-UV-NIR
Fiber spectrometer
Overview:
This spectrometer is designed for spectrum analysis in LED, energy-saving lamps, fluores-cent lamps and many other fields.
Features:
1.Modular design
2.User-configured wavelength range and resolution
3.Automatically reads the wavelength calibration coefficients of the spec-trometer and configures operating software
4.USB-to-PC interface; no external power requirements
S3000-VIS Fiber spectrometer
S3000-VIS |
|
Power supply |
5V DC provided by PC USB port |
Wavelength range |
330 nm- 1100 nm |
Detector |
TCD1305 UV-Enhanced CCD |
Slit |
30um |
Grating |
600line/mm@250nm |
Wavelength resolution |
Depending on grating and slit, minimum to 0.2nm |
S/N ratio |
500:1 |
Scatter light |
<0.1% |
CCD Linearity correction |
99.8% |
Power consumption |
95mA@5V |
Communication interface |
USB2.0/RS232 |
A/D conversion |
16Bit |
Fiber interface |
SMA905 |
Dimension |
115mm(L)*80mm(W)*40mm(H) |
Weight |
500 g |
Minimum exposure time |
0.01ms |
Maximum exposure time |
60s |
Wavelength repeat error |
<0.2nm |
Wavelength absolute error |
<0.5nm |
FWHM |
<1 nm |
Operating temperature |
-40℃~ 85℃ |
Software |
Spectra Pro |
S3000-UV Fiber spectrometer
S3000-UV |
|
Power supply |
5V DC provided by PC USB port |
Wavelength range |
200nm ~ 950nm |
Detector |
TCD1305 UV enhanced CCD |
Slit |
30um |
Grating |
600line/mm@250nm |
Wavelength resolution |
Depending on grating and slit, minimum to 0.2nm |
S/N ratio |
500:1 |
Scatter light |
<0.1% |
CCD Linearity correction |
99.8% |
Power consumption |
95mA@5V |
Communication interface |
USB2.0/RS232 |
A/D conversion |
16 bit high precision AD |
Fiber interface |
SMA905 |
Dimension |
115mm(L)*80mm(W)*40mm(H) |
Weight |
500 g |
Minimum exposure time |
0.01ms |
Maximum exposure time |
60s |
Wavelength repeat error |
<0.2nm |
Wavelength absolute error |
<0.5nm |
FWHM |
<1 nm |
Operating temperature |
-40℃~ 85℃ |
Software |
Spectra Pro |
S3000-UV-NIR Fiber spectrometer
S3000-UV-NIR |
|
Power supply |
5V DC provided by PC USB port |
Wavelength range |
190nm ~ 1100nm |
Detector |
TCD1305 UV enhanced CCD |
Slit |
30um |
Grating |
Dual blazed grating.600line/mm@250nm=750nm |
Wavelength resolution |
Depending on grating and slit, minimum to 0.2nm |
S/N ratio |
500:1 |
Scatter light |
<0.1% |
CCD Linearity correction |
99.8% |
Power consumption |
95mA@5V |
Communication interface |
USB2.0/RS232 |
A/D conversion |
16 bit high precision AD |
Fiber interface |
SMA905 |
Dimension |
115mm(L)*80mm(W)*40mm(H) |
Weight |
500 g |
Minimum exposure time |
0.01ms |
Maximum exposure time |
60s |
Wavelength repeat error |
<0.3 nm |
Wavelength absolute error |
<0.3 nm |
FWHM |
<1 nm |
Operating temperature |
-40℃ ~ 85℃ |
Software |
Spectra Pro |
Overview:
S3000-UV-NIR is a UV spectrometer. This spectrometer is designed for spectrum analysis in food, chemistry, biology and many other fields.