Product List

ALL PRODUCTS (A~Z)

Inquiry Now

  Email:

  hzck@com.hz.cn

  sales@cktrade.com.cn

 

 

   Fax:

  +86-571-87977703

 

 

  Tel:

  +86-571-87977725

  +86-571-87977729

  +86 18969038315

 

 

   Skype:

  ckskyphone

 

 

 

You are here: Home > Products > Biological > PCR Instrument > PR-96E/ PR-384E Gradient ...Products

PR-96E/ PR-384E Gradient PCR Instrument

PR-96E/ PR-384E Gradient PCR Instrument

  • Product description

    Gradient PCR instrument is a gene amplification instrument with gradient PCR function derived from ordinary PCR instrument.It is widely used in molecular biology, criminal investigation, disease research and other fields.
  • Feature

  • 1. New and unique appearance, the interface operation is simple and convenient, compact size.
    2. The latest generation of semiconductor technology, excellent augmentation performance, effectively eliminate the edge effect of module heat conduction, the module temperature uniformity is excellent. Built-in multi-channel refrigeration film, several sensors are evenly distributed, the program temperature control is more precise.
    3. 5-inch TFT high-definition full-touch color screen, can quickly edit the required files, visual display of temperature curve, convenient and fast setting, accurate display of temperature curve and instrument running process status in real time.
    4. The system has a built-in gradient calculator, which can easily obtain accurate annealing temperature for different experimental samples to optimize PCR reaction conditions.
    5. User login, rights management, password protection, data security, administrators can clear users,large data storage, the maximum number of files that can be stored in the machine is greater than 100.
    6. The ingenious elastic hot cover structure design, ADAPTS to the different height test tube, guarantees the best conditions for the test.
    7. Real-time display of gradient temperature distribution, real-tmi e temperature display, more conducive to controlling the sampel temperature.
    8. The hot lid temperature and working mode can be set, hot lid can be switched on and off, and test tube temperature control mode and module temperature control mode can be choose to meet more different experimental requirements.
  • Model

    PR-96E/384E

    Hot cover temp. range

    30~110℃

    Single step time

    1~59m59s(0 is forever)

    Max. steps of the program

    30

    Temp. range

    4~99.9℃(constant temp.: 4℃)

    Program max. cycle nu

    99

    Sample capacity

    96×0.2ml/384×0.04ml

    Time increment/decrement

    -599~+599s

    Max. heating rate

    4.5℃/s

    Temp. increase/decrease

    -9.9~+9.9℃

    Max. cooling rate

    4℃/s

    Program pause function

    Yes

    Temp. uniformity

    ±0.25℃

    16℃ Insulation

    Forever

    Temp. accuracy

    ±0.20℃

    LCD

    5 inch, 800×480 Pixel

    Temp. display resolution

    0.1℃

    Program storage quantity

    >100

    Temp. control method

    Block/Tube

    Communication Interface

    USB 2.0

    Gradient temp. uniformity

    ±0.3℃

    Input power

    100~240V AC6.6~3.1A 50/60Hz

    Gradient temp. accuracy

    ±0.3℃

    Dimensions

    W.205×D.280×H.160mm

    Gradient temp. range

    30~99.9℃

    Net weight

    4.3kgs

    Gradient temp. difference range